該儀器(qi)能夠完成水樣萃(cui)(cui)(cui)取的(de)自(zi)動化,只需操作人員將樣品量(liang)好,導入自(zi)動萃(cui)(cui)(cui)取器(qi),設置選擇萃(cui)(cui)(cui)取時間。 萃(cui)(cui)(cui)取儀可(ke)定時定量(liang)在(zai)萃(cui)(cui)(cui)取瓶(ping)中進行萃(cui)(cui)(cui)取。一次性可(ke)萃(cui)(cui)(cui)取三個50-1000ML的(de)水樣。
應用領域:
用于地(di)表水(shui)、地(di)下水(shui)、生活污(wu)水(shui)、工(gong)(gong)業廢(fei)水(shui)中(zhong)油類測定時,通過CCL4水(shui)樣(yang)萃(cui)取(qu)等操(cao)作。該型號射流萃(cui)取(qu)器應(ying)用在工(gong)(gong)業廢(fei)水(shui)、污(wu)水(shui)的、地(di)表水(shui)、揮發酚的萃(cui)取(qu)工(gong)(gong)作。
技術特點:
該產品可用于實驗室中液- 液萃取工作,例如:測油、測酚等項目。該產品采用射流原理,使被測樣品與萃取劑在回流氣動流中激烈碰撞,起到了混勻、反沖、回流的快速融合萃取效果,加大了樣品與萃取劑的接觸面積,大大提高了萃取效率。
01. 萃取的過程半自動化:CCL4定容萃取瓶,自動萃取;
02. 可同時萃(cui)取一(yi)到三個水樣;
03. 獨創的立體(ti)式定(ding)時(shi)反向回流萃取系統(tong),不(bu)僅提高(gao)萃取效率,而且保證了測量的準確性;
04. 健(jian)康安(an)全:萃取(qu)和(he)清洗過程(cheng)封閉良好,封閉狀(zhuang)態(tai)不(bu)揮(hui)發,最大限度減少了分析人員和(he)CCL4的接觸;
05. 萃(cui)取(qu)系(xi)統采用(yong)全防腐、不親油的四氟材料,且運行(xing)清洗流程,最大限度(du) 地減少高低濃度(du)的交叉污(wu)染;
06. 加裝普通的硅酸鎂層吸柱,可(ke)以過濾動(dong)植物(wu)(wu)油(you)(you),測量石油(you)(you)類和(he)動(dong)植物(wu)(wu)油(you)(you) 類物(wu)(wu)質。
技術(shu)參數:
01. 樣(yang)品取樣(yang)量: 0~1000ml
02. 溶劑取樣量: 25~100ml
03. 同時萃取樣(yang)品數: 三個水(shui)樣(yang)
04. 萃取效率: 98%以上
05. 重復性: RSD﹤5% 加(jia)標(biao)回收率:95%-105%
06. 萃取時間: <2分鐘/個樣品
07. 工(gong)作溫度(du): 1~40℃
10. 工(gong)作電源: (220±22)V, (50±1)Hz, 100VA
本產(chan)品優點:
1、可同時萃取三個樣品
2、清洗方便
3、安裝簡單
4、無勞動強度
按照“GB/T16488-1996水質(zhi) 石(shi)油(you)類(lei)和動植(zhi)物油(you)的(de)(de)測(ce)定 紅外光度(du)法”來測(ce)定油(you)類(lei)時(shi),需要對水樣(yang)進行萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)。用U型(xing)管將萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)瓶(ping)A和B連接(jie)起來,由(you)于萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)溶劑的(de)(de)比重比水大,在(zai)重力的(de)(de)作用下(xia)會相對固(gu)定在(zai)U型(xing)管的(de)(de)位(wei)置(zhi),當真(zhen)(zhen)空泵從萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)瓶(ping)A的(de)(de)一(yi)端(duan)抽氣時(shi),水樣(yang)就會從萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)瓶(ping)B快速(su)穿過(guo)萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)溶劑,進入(ru)到萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)瓶(ping)A中(zhong)(zhong),反(fan)之,當真(zhen)(zhen)空泵從萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)瓶(ping)B的(de)(de)一(yi)端(duan)抽氣時(shi),水樣(yang)就會從萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)瓶(ping)A快速(su)穿過(guo)萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)溶劑進入(ru)到萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)瓶(ping)B中(zhong)(zhong),用時(shi)間繼電器控制總萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)時(shi)間和切換抽氣的(de)(de)時(shi)間,就可(ke)以將油(you)類(lei)物質(zhi)從水中(zhong)(zhong)萃(cui)(cui)取(qu)(qu)(qu)(qu)(qu)出來。
技(ji)術指(zhi)標(biao)
1.萃取(qu)水(shui)樣體積:50mL~1000 mL
2.萃取容(rong)劑體(ti)積:25mL~50 mL
3.萃取(qu)效率:95%以(yi)上
4.重復性:RSD﹤5%
5.萃取(qu)時(shi)間:2~12min/個(ge)樣品(萃取(qu)時(shi)間可調)
6.功耗:60VA
7.外型(xing)尺(chi)寸: 500ml萃(cui)取瓶480mm×280mm×700mm 1000ml萃(cui)取瓶480mm×280mm×820mm
AE01型自動萃取(qu)(qu)器一次可萃取(qu)(qu)一個樣品
AE03型自動萃(cui)(cui)取器一次可萃(cui)(cui)取三個樣品
應用領域
用于地表水、地下水、生活污水、工業廢水中油類測定前的萃取,還可用于其它液液萃取。
主要特點:
與傳統萃取方法的比較
指標:自動萃取器/分液漏斗手工萃取
安全性:
自動萃取器:操作人員不直接接觸四氯化碳,安全性高。
分液漏斗手工萃取:操作人員在操作工程中需要開啟分液漏斗的活塞排氣,人體接觸四氯化碳,安全性差。
萃取效率
自動萃取器:氣泵的氣量可以自行調節,萃取溶劑和水樣充分接觸,萃取效率高。
分液漏斗手工萃取:相對萃取效率低。
重復性
自動萃取器:條件設定以后,無需人工干預,純機械運作,重復性好。
分液漏斗手工萃取:人工影響較大,條件不恒定,重復性較差。
勞動強度
自動萃取器:全部自動化操作,并且可以同時萃取多個樣品,勞動強度小。
分液漏斗手工萃取:當需要萃取的水樣體積較大或者樣品較多時,勞動強度很大。
![]() |
![]() |